Gas Analyzer

Portable Carbon Dioxide Purity Analyzer

Approx Price: Rs 1.19 Lakh / Unit 
Minimum Order Quantity: 50 Unit
Product Details:
  • Brand: ATS
  • Model: 202A
  • Application: Laboratory Use
  • Alarm: Audible -Visual Alarm for Low Battery
  • Dimension (Millimeter): 170 (L) x 100 (W) x 130 (H)
  • Display (Inch): 128 x 64 Graphics LCD
  • Make: ATS
  • Resolution Ratio (%): 0.1%
  • Response Time: Less Then 10 Seconds
  • Warranty: One Year
  • Weight (Kilogram): 1.5 Kg

Portable Carbon dioxide Purity Analyser - ATS 202A
The Carbon dioxide Purity and Purge Gas analyzer have been design especially for cylindrical and power station to check the Carbon dioxide Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features: Simple Low Cost maintenance Microcontroller based embedded intelligent 

Specification instruments
H2 gas Range : 85-100%V/V Optional Tri Gas Range 0-100% CO2 in Air , 0-100% H2 In CO2 and 90-100%H2 in Air User friendly Interface Direct Plug In Or Auto Suction Sampling 128 x 64 Graphics LCD Display USB/RS 232 Computer Interface Long Life Rechargeable Li-IONE Battery Specification: Principle Thermal Conductivity and NDIR (Non dispersive Infrared ) Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In Display 128 X 64 Graphics LCD Alarm Two Levels Low High Visual and Audible Power Source Built in Lithium Rechargeable battery Accuracy /2% Response Time Data Storage 5000 or 10000 Computer Interface RS 232, USB, RS485 Sensor Life 4-5 Years Operating Time 6 8 hours Environmental Temperature 15degree Celsius Humidity Atmosphere Pressure 86- 106Kpa Housing High Impact Plastic Dimension in mm 200 (W) X 120 (H) X 185(D) Weight 1.5 KG Warranty One Year


Application:Analysis MAP (Food Gas Packaging) Gasification Syngas Metal Heat Treatment Plant Laboratories Institutions Treatment Process Chemical Industries Petrochemical Pharmaceutical Industries


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 100
  • Delivery Time: 2-3 Weeks
  • Packaging Details: Normal Packing with thermocol

Portable Hydrogen Purity Analyzer

Approx Price: Rs 1.19 Lakh / Unit 
Minimum Order Quantity: 50 Unit
Product Details:
  • Brand: ATS
  • Model: 202

Portable Hydrogen Purity Analyser - ATS 202A
The Hydrogen Purity and Purge Gas analyzer have been design especially for cylindrical and power station to check the Hydrogen Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features: Simple Low Cost maintenance Microcontroller based embedded intelligent

Specification instruments H2 gas Range : 85-100%V/V Optional Tri Gas Range 0-100% CO2 in Air , 0-100% H2 In CO2 and 90-100%H2 in Air User friendly Interface Direct Plug In Or Auto Suction Sampling 128 x 64 Graphics LCD Display USB/RS 232 Computer Interface Long Life Rechargeable Li-IONE Battery Specification: Principle Thermal Conductivity and NDIR (Non dispersive Infrared ) Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In Display 128 X 64 Graphics LCD Alarm Two Levels Low High Visual and Audible Power Source Built in Lithium Rechargeable battery Accuracy /2% Response Time Data Storage 5000 or 10000 Computer Interface RS 232, USB, RS485 Sensor Life 4-5 Years Operating Time 6 8 hours Environmental Temperature 15degree Celsius Humidity Atmosphere Pressure 86- 106Kpa Housing High Impact Plastic Dimension in mm 200 (W) X 120 (H) X 185(D) Weight 1.5 KG Warranty One Year Application: Hydrogen Cooled Alternators Turbine Hydrogen Analysis MAP (Food Gas Packaging) Gasification Syngas Metal Heat Treatment Plant Laboratories Institutions Treatment Process Chemical Industries Petrochemical Pharmaceutical Industries

Portable Nitrogen Purity Analyzer

Approx Price: Rs 65,500 / Unit 
Minimum Order Quantity: 50 Unit
Product Details:
  • Brand/Make: ATS
  • Automatic Grade: Automatic

Portable Nitrogen Purity Analyzer ATS 202A.
Specification;
Sensor : EC
Range: 0-100% V/V
Accuracy : +/-1%
Display: Highy Quality 128X 65 Graphics LCD
Sampling: Auto Suction  Sampling through  Inbuilt Pump
Zero Calibration: Automatic  at instument start up  with fresh air sample
Powe Supply:Rechargeable Ni-cad Battery pack with  charger
Response Time:30 Seconds at 95% Variation
Data logger
Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 100
  • Delivery Time: 2-3 Weeks
  • Packaging Details: Normal Packing with thermocol

Portable Oxygen Purity Analyzer

Approx Price: Rs 65,500 / Unit 
Minimum Order Quantity: 50 Unit
Product Details:
  • Brand: ATS
  • Model: 202A

Portable Oxygen Purity Analyser - ATS 202A
The Oxygen Purity and Purge Gas analyzer have been design especially for cylindrical and power station to check the Hydrogen Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features: Simple Low Cost maintenance Microcontroller based embedded intelligent 

Specification instruments
H2 gas Range : 85-100%V/V Optional Tri Gas Range 0-100% CO2 in Air , 0-100% H2 In CO2 and 90-100%H2 in Air User friendly Interface Direct Plug In Or Auto Suction Sampling 128 x 64 Graphics LCD Display USB/RS 232 Computer Interface Long Life Rechargeable Li-IONE Battery Specification: Principle Thermal Conductivity and NDIR (Non dispersive Infrared ) Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In Display 128 X 64 Graphics LCD Alarm Two Levels Low High Visual and Audible Power Source Built in Lithium Rechargeable battery Accuracy /2% Response Time Data Storage 5000 or 10000 Computer Interface RS 232, USB, RS485 Sensor Life 4-5 Years Operating Time 6 8 hours Environmental Temperature 15degree Celsius Humidity Atmosphere Pressure 86- 106Kpa Housing High Impact Plastic Dimension in mm 200 (W) X 120 (H) X 185(D) Weight 1.5 KG Warranty One Year


Application:Analysis MAP (Food Gas Packaging) Gasification Syngas Metal Heat Treatment Plant Laboratories Institutions Treatment Process Chemical Industries Petrochemical Pharmaceutical Industries


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Mumbai
  • Production Capacity: 100
  • Delivery Time: 2-3 Weeks
  • Packaging Details: Normal Packing with thermocol
Looking for Gas Analyzer ?
Share Us:
© Applied Techno Systems
Desktop Site Back to top